tf20_interface
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| tf20_interface [2023/03/22 16:30] – crucifix | tf20_interface [2023/11/01 20:18] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 49: | Line 49: | ||
| ---- | ---- | ||
| - | ===== The TEM User Interface (TEM) ===== | + | ===== The TEM User Interface (TUI) ===== |
| **Location**: | **Location**: | ||
| Line 56: | Line 56: | ||
| - | * ++It is divided into 4 zones: | + | |
| - | </ | + | |
| + | | ||
| + | | ||
| + | *Zone 3 : | ||
| + | | ||
| + | {{: | ||
| + | </ | ||
| * ++The beginner user will use it to: | * ++The beginner user will use it to: | ||
| - | * dock/undock the cassette from the NanoCab to the autoloader. | ||
| * load/unload the grids in the column. | * load/unload the grids in the column. | ||
| * change and center the Condenser 2 and objective apertures. | * change and center the Condenser 2 and objective apertures. | ||
| - | * control the autoloader | + | * control the turbo pump. |
| * perform beam-shift adjustments. | * perform beam-shift adjustments. | ||
| * manually set eucentric height. | * manually set eucentric height. | ||
| Line 71: | Line 75: | ||
| * align the microscope. | * align the microscope. | ||
| * troubleshoot the system. | * troubleshoot the system. | ||
| - | * manage the cold system. | ||
| * perform cryo-cycle of the column/ | * perform cryo-cycle of the column/ | ||
| </ | </ | ||
| + | |||
| ---- | ---- | ||
| - | The FluCam User Interface (FC) | + | ===== The FluCam User Interface (FC) ===== |
| - | Location: On the right screen | + | **Location**: On the right screen |
| - | Role: It allows the visualization of the electron beam and the sample image. | + | **Role:** It allows the visualization of the electron beam and the sample image. |
| + | |||
| + | * ++The beginner user will use it to: | ||
| + | * record the Atlases. | ||
| + | * select squares and prepare the square maps at eucentric height. | ||
| + | * select targets (position). | ||
| + | * screen targets at higher magnification (as single image or montage). | ||
| + | * center the different beam modes all together on the camera axis. | ||
| + | </ | ||
| + | |||
| + | * ++The expert user will use it to: | ||
| + | * record the Atlases. | ||
| + | </ | ||
| + | |||
| + | | ||
| - | The beginner user will use it to: | ||
| - | The expert user will use it to: | ||
tf20_interface.1679502648.txt.gz · Last modified: (external edit)