| Line 1: | Line 1: | ||
| - | ===== The Glacios microscope interfaces ===== | + | ====== The Glacios microscope interfaces |
| Line 16: | Line 16: | ||
| ---- | ---- | ||
| - | ===== Gatan DigitalMicrograph (DM) ===== | + | ===== Gatan DigitalMicrograph |
| **Location**: | **Location**: | ||
| Line 33: | Line 33: | ||
| ---- | ---- | ||
| - | ===== SerialRM | + | ===== SerialEM |
| **Location**: | **Location**: | ||
| Line 39: | Line 39: | ||
| **Role**: It provides camera/ | **Role**: It provides camera/ | ||
| - | * ==The beginner user will use it to: | + | * ++The beginner user will use it to: |
| * record the Atlases. | * record the Atlases. | ||
| * select squares and prepare the square maps at eucentric height. | * select squares and prepare the square maps at eucentric height. | ||
| Line 53: | Line 53: | ||
| * center the different beam modes all together on the camera axis. | * center the different beam modes all together on the camera axis. | ||
| </ | </ | ||
| + | |||
| + | ---- | ||
| + | |||
| + | ===== The TEM User Interface (TEM) ===== | ||
| + | |||
| + | **Location**: | ||
| + | |||
| + | **Role**: It controls all the microscope systems. | ||
| + | |||
| + | * ++The beginner user will use it to: | ||
| + | * dock/undock the cassette from the NanoCab to the autoloader. | ||
| + | * load/unload the grids in the column. | ||
| + | * change and center the Condenser 2 and objective apertures. | ||
| + | * control the autoloader turbo pump. | ||
| + | * perform beam-shift adjustments. | ||
| + | * manually set eucentric height. | ||
| + | </ | ||
| + | * ++The expert user will use it to: | ||
| + | * perform all the actions described above. | ||
| + | * align the microscope. | ||
| + | * troubleshoot the system. | ||
| + | * manage the cold system. | ||
| + | * perform cryo-cycle of the column/ | ||
| + | </ | ||
| + | |||
| + | ---- | ||
| + | |||
| + | ===== The FluCam User Interface (FC) ===== | ||
| + | |||
| + | **Location**: | ||
| + | |||
| + | **Role**: It allows the visualization of the electron beam and the sample image. | ||
| + | |||
| + | * ++The beginner user will use it to: | ||
| + | * center the beams. | ||
| + | * center Condenser 2 and objective apertures. | ||
| + | * look for and move to particular features on their grids. | ||
| + | * manually set eucentric height. | ||
| + | </ | ||
| + | * ++The expert user will use it to: | ||
| + | * perform all the actions described above. | ||
| + | * align the microscope. | ||
| + | </ | ||
| + | |||